Auto-Set™ Technical Specifications: |
|
Literature: |
|
|
• Power Supply - 120/240 VAC or 24 VDC (Universal Supply) |
|
• Product Datasheet |
|
|
• Operating Temperature -25 °F (-32 °C) to 160 °F (71 °C) |
|
• Full Line Product Catalog |
|
|
• Sensitivity - 0.5 Pico Farad |
|
(See Downloads for more literature) |
|
|
• Output - 1 Set Voltage Free Changeover Relay Contact |
|
|
|
|
• Fail Safe - Low Level or High Level (Selectable) |
|
Technical: |
|
|
• Calibration - Push Button (With or Without Material) |
|
• Product Manual |
|
|
• LED Display - Measured Values (Covered, Uncovered, Trip) |
|
|
|
|
• LED Indicator - Material Detection |
|
Product Dimensions: |
|
|
• Time Delay - 0 to 60 Seconds |
|
ATS7V0FC - |
|
|
• Power Shield - 3-7/8 Inch (ATS7V0FC) |
|
• .dwg (AutoCAD) .pdf |
|
|
12-1/16 Inch (ATS70FC-300) |
|
|
|
|
15-5/16 Inch (ATS7V0FC-400) |
|
ATS7V0FC-300 - |
|
|
• Probes - Stainless Steel (3 Inches to 33 Feet) |
|
• .dwg (AutoCAD) .pdf |
|
|
• Conduit Entry - 3/4 Inch NPT (2) |
|
|
|
|
• Enclosure - Flame Retardant, Glass Reinforced Nylon |
|
Compare Level Indicators |
|
|
• Protection - IP65, NEMA 4 |
|
|
|
|
|
|
|
|
|
Approvals: |
|
|
|
|
• CSA Class II Div 1 Groups E, F & G (U.S. & Canada) |
|
|
|
|
• ATEX & CE Versions Available |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Part Numbers and Accessories: |
|
|
|
|
• ATS7V0FC ~ Auto-Set (Container Walls Up To 3 Inches Thick) |
|
|
|
|
• ATS7V0FC-300 ~ Auto-Set (Container Walls 3 to 11 Inches Thick) |
|
|
|
|
• ATS7V0FC-400 ~ Auto-Set (Container Walls 11 to 14.5 Inches Thick) |
|
|
|
|
• EX03 ~ 316 Stainless Steel 3-3/8 Inch Probe |
|
|
|
|
• EX12 ~ 316 Stainless Steel 8 Inch Probe |
|
|
|
|
• EX24 ~ 316 Stainless Steel 20 Inch Probe |
|
|
|
|
• EX36 ~ 316 Stainless Steel 32 Inch Probe |
|
|
|
|
• EX48 ~ 316 Stainless Steel 44 Inch Probe (M/F Threaded Ends) |
|
|
|
|
• WP ~ 304 Stainless Steel Probe Wire |
|
|
|
|
• SMP ~ Mounting Plate (Stainless Available) |
|
|
|
|
|
|
|
|