| Model |
|
 |
 |
 |
 |
 |
 |
 |
| M800
Speedswitch |
M3001
Slipswitch
|
M3005
Slipswitch
|
M100
Stopswitch
|
P80010
Proxswitch
|
P80034
Proxswitch
|
WDA
High Power |
| |
|
| Description |
Intelligent Underspeed Switch with 3 outputs
|
Intelligent Underspeed Switch with one output |
Intelligent Underspeed Switch with one output |
Stopped Motion Monitor |
Simple Inductive Proxy. |
Simple Inductive Proxy. |
Simple Magnetic Proxy reluctance sensor |
| |
|
| Features |
Totally Sealed
Auto Calibration
½” conduit entry
|
Totally Sealed
Auto Calibration
2-wire
|
Totally Sealed
Auto Calibration
3/5-wire
|
18mm Cylindrical
4 Second delay
2-wire
|
Totally sealed
LED’s
1/2 “ conduit entry
|
Totally sealed
LED’s
1/2 “ conduit entry
|
Adjustable Sensing Range 1 to 4” Molded
Bracket Included
½” conduit entry |
| |
|
| Style |
DIN |
30mm
Cylindrical
|
30mm
Cylindrical
|
18mm dia
Cylindrical
|
DIN |
DIN |
2”
Cylindrical |
| |
|
| Supply Voltage |
120VAC
220VAC
24VDC
(Must Specify)
|
24 to 240 vac
12 to 240 vdc
(Universal)
|
24 to 240 vac
12 to 240 vdc
(Universal)
|
24 to 240 vac
12 to 240 vdc
(Universal)
|
24 to 240 vac
12 to 240 vdc
(Universal)
|
10 to 30 vdc |
12 to 24 vdc |
| |
|
| Output |
1 x 10% underspeed Relay
1 x 20% underspeed Relay
1 x NPN Transistor pulse |
1 x 20% underspeed Triac with maximum load of
200mA |
1 x 20% underspeed Relay
OR
1 x 20% underspeed NPN/PNP Transistor
(Specify)
|
Stopped motion signal. Tiac with maximum load
of 200mA |
1 x SPST Relay 3 Amp |
1 x NPN/PNP Transistor |
1 x PNP Transistor |
| |
|
| Approvals |
US and Canadian
Class 2 Div. 1
E, F, G.
CE
|
US and Canadian
Class 2 Div. 1
E, F, G
CE
|
US and Canadian
Class 2 Div. 1
E, F, G
Europe - ATEX and CE |
US and Canadian
Class 2 Div. 1
E, F, G
Europe - CE
|
US and Canadian
Class 2 Div. 1
E, F, G
Europe - CE
|
US and Canadian
Class 2 Div. 1
E, F, G
Europe - CE
|
US and Canadian
Class 2 Div. 1
E, F, G
Europe - CE
|
| |
|
| Applications |
Conveyors, Bucket Elevators, any speed sensitive
shaft for automatic underspeed detection with 10% alarm and 20%
shutdown |
Conveyors, Bucket Elevators, any speed sensitive
shaft for automatic 20% underspeed detection. |
Conveyors, Bucket Elevators, any speed sensitive
shaft for automatic 20% underspeed detection. |
Process control. Provides a signal 4 seconds after
the shaft has stopped. |
Speed input for display, control or PLC.
Also used as an inductive limit switch for gates and arms.
|
Speed input for display, control or PLC.
Also used as an inductive limit switch for gates and arms.
|
Conveyors, Bucket Elevators, any speed sensitive
shaft. Used for applications where an extended sensing range
of up to 4”
is required. Can detect moving ferrous object behind a stainless
steel plate. |